Wear Resistance Data

RTP 2200 Series Polyetheretherketone (PEEK) Compounds — English Units

[photo]

Wear factor (K) is an indication of a materials resistance to wear as a function of the volume of material lost, force (load) and velocity at the wear interface and time. It is often determined using a "thrust washer" wear testing apparatus per ASTM D3702 in which a molded plastic specimen is rotated against a substrate thrust washer under set pressure and velocity conditions.

A wear factor is calculated with the equation W=K*F*V*T. In this equation W is wear volume (in3), K is wear factor (in3 min/ft lb hr)10-10, F is force (lb), V is velocity (ft/min), and T is elapsed time (hr).

A material with a lower wear factor (K) has greater resistance to wear and these values are useful for material comparison purposes.


[ View wear data in metric units | Return to wear data resin list ]

Plastic vs Steel

RTP Product Tested vs. Steel (1018 C)
PV 2000
Load 8
Speed 50
PV 5000
Load 10
Speed 100
PV 10000
Load 40
Speed 50
Wear
Factor
µ
Dynamic
Wear
Factor
µ
Dynamic
Wear
Factor
µ
Dynamic
RTP 2200 LF TFE 15
15% PTFE
122 0.26 105 0.50    
RTP 2200 LF TFE 20
20% PTFE
83 0.22 67 0.37    
RTP 2200 HF TFE 50
50% PTFE
4 0.26 6 0.26 4 0.16
RTP 2205 HF TFE 15
30% Glass Fiber
15% PTFE
74 0.48 61 0.61 73 0.32
RTP 2285 HF TFE 15
30% Carbon Fiber
15% PTFE
47 0.37 47 0.37 45 0.65
RTP 2200 HF AR 15 TFE 15
15% Aramid Fiber
15% PTFE
6 0.28 15 0.24 42 0.30
  • Thrust washer testing conducted per ASTM D 3702
  • Wear Factor units: (in3 min/ft lb hr)10-10
  • PV units: lb ft/in2 min
  • Load units: lb
  • Speed units: ft/min

Comparing competitive data note

  • RTP Company reports Wear Factors per unit Force (KF) with units of (in3 min/ft lb hr)10-10. This is the industry standard way to calculate and report Wear Factor. Some suppliers report Wear Factors per unit Pressure (KP) with units of (in5 min/ft lb hr)10-10. This value is arrived at by dividing the KF by the contact surface of the test specimen (0.35 in2). As result of this reporting discrepency, RTP Company's Wear Factor values appear to be significantly higher. For example a KP of 3 (in5 min/ft lb hr)10-10 would be equal to KF of 3/0.35 = 8.57 (in3 min/ft lb hr)10-10.

No information supplied by RTP Company constitutes a warranty regarding product performance or use. Any information regarding performance or use is only offered as suggestion for investigation for use, based upon RTP Company or other customer experience. RTP Company makes no warranties, expressed or implied, concerning the suitability or fitness of any of its products for any particular purpose. It is the responsibility of the customer to determine that the product is safe, lawful and technically suitable for the intended use. The disclosure of information herein is not a license to operate under, or a recommendation to infringe any patents.