UL Recognized Tradename Precolored Resins

RTP Company has the ability to precolor select grades of resin from major polymer manufacturers and maintain their UL Recognition.

  • These products are covered under UL file number E147133
  • RTP Company can not yellow cards for these products
Product Color Thickness Flame
Class
Glow Wire Rating Relative Thermal Index H
W
I
H
A
I
H
V
T
R
D
4
9
5
C
T
I
Inch mm GWIT GWFI Elect Mech
w/ imp
Mech
w/o imp
Lexan® 920 (f1) All 1/16 1.5 V-0     130 120 125 3 3 4    
All 1/8 3.0 V-0     130 120 130 2 3 4 7 2
Lexan® 940 (f1) All 0.044 1.1 V-0     80 80 80 3 4      
All 1/16 1.5 V-0     130 120 125 3 3      
All 1/8 3.0 V-0     130 120 130 2 3 3 7 2
Lexan® 920 A, 940 A All 1/16 1.5 V-2     130 120 125 3 1      
All 0.090 2.3 V-2     130 120 125 3 -      
All 1/8 3.0 V-0     130 120 130 2 3 3 7 2
Cycolac® KJB (f2), KJW (f2) BL, GN 1/16 1.5 V-0, RP75     60 60 60 3 0      
BL, GN 0.080 2.0 V-0, 5V-B     60 60 60 - -      
BL, GN 0.110 2.8 V-0, 5V-A     60 60 60 - -      
BL, GN 1/8 3.0 V-0/5V-A     60 60 60 1 0 4 6 1
BL, GN 1/4 6.0 V-0, 5V-A     60 60 60 0 0      
($) 1/16 1.5 V-0, RP75     90 85 90 3 0      
($) 0.080 2.0 V-0, 5V-B     90 85 90 - -      
($) 0.110 2.8 V-0, 5V-A     90 85 90 - -      
($) 1/8 3.0 V-0, 5V-A     90 85 90 1 0 4 6 1
($) 1/4 6.0 V-0, 5V-A     90 85 90 0 0      
Cycolac® KJU All 1/16 1.5 V-0     60 60 60 4 0      
All 0.110 2.8 V-0/5V-A     60 60 60 - -      
All 1/8 3.0 V-0/5V-A     60 60 60 3 2 4 7 1
All 1/4 6.0 V-0/5V-A     60 60 60 2 2      
Cycolac® T (f2) BL, GN 1/16 1.5 HB     60 60 60 4 0      
BL, GN 1/8 3.0 HB     60 60 60 3 0 3 6 0
BL, GN 1/4 6.0 HB     60 60 60 3 0      
($) 1/16 1.5 HB     65 80 65 4 0      
($) 1/8 3.0 HB     65 80 65 3 0 3 6 0
($) 1/4 6.0 HB     65 80 65 3 0      
Cycolac® V-100 All 1/16 1.5 V-0     60 60 60 0 0      
All 0.100 2.5 V-0, 5V-A     60 60 60 0 0      
All 1/8 3.0 V-0, 5V-A     60 60 60 0 0 2 6 0
Cycolac® V-200 All 1/32 0.75 HB     60 60 60 - -      
All 1/16 1.5 V-0     60 60 60 3 0      
All 0.100 2.5 V-0, 5V-A     60 60 60 - -      
All 1/8 3.0 V-0, 5V-A     60 60 60 0 0 3 6 0
Cycolac® VW-300 (f2) All 1/16 1.5 V-0     60 60 60 3 1      
All 0.080 2.0 V-0, 5V-A     60 60 60 2 -      
All 0.087 2.2 V-0, 5V-A     60 60 60 0 -      
All 1/8 3.0 V-0, 5V-A     60 60 60 0 0 3 6 1
Product Color Inch mm Flame
Class
GWIT GWFI Elect Mech
w/ imp
Mech
w/o imp
H
W
I
H
A
I
H
V
T
R
D
4
9
5
C
T
I
Thickness Glow Wire Rating Relative Thermal Index

PermaStat® is a registered trademark of RTP Company
Lexan® is a registered trademark of SABIC Innovative Plastics
Cycolac® is a registered trademark of SABIC Innovative Plastics
Bayblend® is a registered trademark of Bayer

"Yellow card" documentation for RTP Company compounds that are UL Recognized are available through the UL iQ for Plastics online certifications directory, our file number is E84658, or through the UL IDES Prospector materials database.

Notes:

  • (a) = the last digit can be replaced with any integer from 1 - 7
  • (b) = the last digit can be replaced with any number from 0.5 - 7
  • (c) = the last digit can be replaced with any number from 0 - 5
  • (d) = "y" may be omitted or replaced with the letter "C"
  • (e) = the last digit can be replaced with any integer from 0 - 2
  • (f1) = certified for outdoor use with respect to exposure to UV light, water exposure and immersion in accordance with UL746C
  • (f2) = certified for outdoor use with respect to one or more of the following tests: UV, water exposure or immersion in accordance with UL746C
  • (g) = the last digit can be replaced with any number from 0.5 - 3
  • (h) = the last digit can be replaced with any number from 0 - 3
  • (i) = the last digit can be replaced with any number from 0 - 2
  • (j) = the letter can be replaced with any letter from A to G
  • (K) = represents a single letter A-I inclusive
  • (l) = represents a single number within the range of 5-15
  • (m) = the letter may be replaced with any letter from C to F, which represent the corresponding LGF levels:
  • C = 30%, D = 35%, E = 40%, F = 45%.
  • (n) = the letter should be replaced with a number, 5 - 10, inclusive.
  • (o) = the letter should be replaced with a number from the following set: [3, 3.1,3.2, 3.3, 3.4, 4, 4.1, 4.2, 4.3, 4.4, 5].
  • (p) = the letter should be replaced with a number, 5 - 20, inclusive.
  • (q) = the letter should be replaced with a number, 1 - 5, inclusive.
  • (r) - May be manufactured in 60A Shore Hardness
  • (rg) - Virgin and regrind up to 50% by wt. incl. have the same basic flammability characteristics when used within the 50C generic RTI.
  • (rg2) - Virgin and regrind up to 50% by wt. incl. have the same basic flammability characteristics when used within the 65C generic RTI.
  • (rg3) - Virgin and regrind up to 70% by wt. incl. have the same basic flammability characteristics when used within the 50C generic RTI.
  • (rg4) - Virgin and regrind up to 70% by wt. incl. have the same basic flammability characteristics when used within the 65C generic RTI.
  • (s) - May be manufactured in 75A Shore Hardness
  • (t) - May be manufactured in 35D Shore Hardness
  • (u) - The average time to track @ 2500V was 7 minutes
  • (+) = UL will allow up to 50% regrind in this product
  • ($) = Represents all colors except blue and green.